Correct Electrical Deficiencies

Solicitation (Invitation for bids) from 246-Network Contracting Office 6 (36c246). Responses are due Dec 8, 2026 (18 days left).

Service-disabled veteran-owned (SDVOSB)Reserved for small firms owned and run by service-disabled veterans.Who qualifies
  • 18Days left to respond
  • 12 daysThis buyer usually gives
  • 28%Notices this buyer changes
  • $379KTypical award from this office

What BidCamel found about this buyer

  • This office usually gives bidders 12 days to respond; this notice gives 78 days.
  • It changed 28% of its 111 notices after posting, so check for amendments before you submit.
  • It has 11 open bids right now. See them all.
  • It has made 21 awards in our records, typically $379K.

Companies this office paid before

  • Cavu Consulting Llc: 2 awards, $251K total
  • Sun Control Systems Llc: 2 awards, $72K total
  • Zonaestilo, Llc: 2 awards, $69K total
  • Durham Exchange Club Industries, Inc: 1 award, $7.0M total
  • Jett'S Specialty Contracting, Llc: 1 award, $4.9M total

These are past winners at this office, not the winner of this exact contract.

Key details
Solicitation number
36C24627B0001
NAICS code
236220 Commercial and Institutional Building Construction
Size standard for this code
45 million dollars in average annual revenue
Set-aside
Service-disabled veteran-owned (SDVOSB)
Buying
Product
Place
Fayetteville, NC ยท North Carolina bids
Posted
Sep 21, 2026
Last changed
Nov 5, 2026 (3 versions)
Contact
Contact details are on the SAM.gov notice. Open on SAM.gov

Description

SOW 565-22-500 Correct Electrical Deficiencies Fayetteville VAMC Intent The project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. Period of performance 1,174 calendar days. Medium Voltage VA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope: Replace existing medium voltage entrance equipment with new at campus entrance. Provide new building: Slab on grade, brick on CMU wall, Slate roof tile (to match existing facility) Provide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 . Demo and remove old VA owned medium voltage entrance metal shack. Replace medium voltage sectionalized switch. Provide new metal-clad switchgear with draw-out vacuum circuit breakers. Replace medium voltage oil filled transformer (1) Panel Replacement and Branch Circuit Improvements Correct deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include: Replace-in-same-room building entrance and large distribution equipment: Normal (service entrance) Switchboards: approx. 2 Generator switchboards: approx. 2 Automatic transfer switch: approx. 7 Replace-in-place distribution panels and panelboards distribution equipment Distribution Panels: approx. 5 Panelboards: approx. 68 Replace undersized feeders Redundant Gound Provide redundant equipment grounding conductor to a portion of the facility. Approx. 100,000 square feet of existing electrical branch circuit distribution in occupied space. HVAC And Plumbing Reroute (vertically & horizontally) Sewer piping and hot water piping to avoid electrical room. Provide exhaust fan to new Medium Voltage building. Incidental Electrical Equipment Cleanup Provide Identification tag to new and existing equipment throughout the facility: approx. 100 tags Clean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures. Correct panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels. ALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.

Read the full notice and attachments on SAM.gov

Similar open bids

All open bids for NAICS 236220

From SAM.gov and USAspending.gov public data. BidCamel adds the buyer and award facts.

Save and get alerts